Skip to main content

Component TE-100 Implants with Tylan (Canada)

This treatment applies to the following species:
Company: Elanco

(trenbolone acetate, estradiol and tylosin tartrate)

STEERS

HEIFERS

DIN 02366916

FOR VETERINARY USE ONLY

FOR FEEDLOT STEERS AND HEIFERS

20 DOSE CARTRIDGE BELT

For use with a Component Implanter.

Description

COMPONENT TE-100 Implants with Tylan is an implant containing 100 mg of trenbolone acetate USP, 10 mg of estradiol USP and 29 mg of tylosin tartrate.

Component TE-100 Implants with Tylan Indications

This product contains trenbolone acetate and estradiol, in a slow-release delivery system, which increases rate of weight gain and improves feed efficiency in feedlot steers and heifers. Tylan (tylosin tartrate) is included as a local antibacterial for reducing the incidence of abscess formation at the implant site.

NOTE: The administration of COMPONENT TE-100 Implants with Tylan can result in decreased marbling compared to non-implanted steers and heifers. Efficacy was confirmed in a growth-performance trial conducted in yearling steers weighing between 475 and 565 kg at the time of implantation and in yearling heifers weighing between 450 and 510 kg at the time of implantation.

Dosage: One implant containing 100 mg trenbolone acetate and 10 mg estradiol and 29 mg of tylosin tartrate is administered to each animal. The six pellets (five trenbolone acetate/estradiol pellets and one tylosin tartrate pellet) which make up the dosage of COMPONENT TE-100 Implants with Tylan are contained in one division of the multiple dose cartridge belt. Twenty doses are in each cartridge belt. The cartridge belt is designed to be used with a Component Implanter.

Cautions: For use in feedlot steers and heifers only. Do not use in young calves (less than 300 kg body weight), spayed heifers or in heifers intended for subsequent breeding.

Warnings

Do not use in calves to be processed for veal. For use in feedlot steers and heifers only. Implant pellets in the ear only. Do not attempt salvage of implanted site for human or animal food. Do not use in dairy cattle. Keep out of reach of children.

Storage

Store unopened product at or below 25°C. Avoid excessive heat and humidity. Use product before the expiration date printed on the carton and the foil pouches. Discard open foil pouches.

Implanter Instructions

General Instructions

Study the instructions which should be followed carefully at all times. Avoid short cuts. Skin infections can be avoided by properly preparing implant site. During fly season use fly repellent on implant site. One designated team member should always do the implanting. Cleanliness of hands and instruments is important at all times.

Loading The Implanter

Load the implanter following the instructions supplied with each implanter.

Restrain The Animal

Speed of implantation as well as safety of handlers is best achieved by restraining animal in a squeeze chute using head restraint. When implanting horned cattle, better control is obtained with additional use of nose tongs.

Prepare The Implant Site

Scrub the back side of the ear (implant site) with a piece of clean absorbent cotton which has been soaked with a topical germicidal solution. Follow manufacturer’s directions on germicide for correct strength and preparation of solution. Avoid getting in animal’s eyes.

Where To Implant

The full contents of the cartridge (all 6 pellets) should be implanted beneath the skin on the back side of the middle one-third of the ear as illustrated in the drawing. The implant must not be closer to the head than the edge of auricular cartilage ring farthest from the head. The location for insertion of the needle is a point towards the tip of the ear at least a needle length away from the intended deposition site. Avoid injuring the arteries, veins and cartilage of the ear.

Insert The Needle

With one hand firmly grasp the ear. With other hand insert needle point through the skin and ease forward on a lateral plane until the entire length of the needle is under the skin.

Implant The Pellets

After inserting the needle fully in the correct implant position squeeze the trigger fully as the needle is withdrawn from the ear. This properly deposits the implant in the needle track. This procedure should prevent breakage or crushing of pellets if otherwise forced into contact with tough fibrous-tissue underlying the skin. The length and total contact area of the single dose are designed to permit absorption of the hormones after implantation to stimulate good weight gain. Broken or crushed pellets may interfere with rates of gain.

Clean The Needle

Disinfect the implanter needle with a germicidal solution prior to implanting the next animal.

Contains: 100 Implants; five (5) cartridge belts of 20 implants each, sealed in sanitary foil pouches.

U.S. Patent No. 5,874,098

Component, Tylan, Elanco and the diagonal bar logo are trademarks of Elanco or its affiliates.

©2022 Elanco or its affiliates.

Manufactured by Elanco Canada Limited, 1919 Minnesota Court, Suite 401, Mississauga, Ontario L5N 0C9

AH0515

21Jan2022

CPN: 1231143.2

ELANCO CANADA LIMITED
1919 MINNESOTA COURT, SUITE 401, MISSISSAUGA, ON, L5N 0C9
Customer Service:   800-265-5475
Fax:   519-821-7831
Website:   www.elanco.ca
Email:   elancocanadacustomerservice@elancoah.com
THIS SERVICE AND DATA ARE PROVIDED "AS IS". Animalytix assumes no liability, and each user assumes full risk, responsibility, and liability, related to its use of the Animalytix service and data. See the Terms of Use for further details.

Animalytix

Copyright © 2024 Animalytix LLC. Updated: 2024-02-27